356 Call Server commands
.stat 2
00 = UNIT 00 = DSBL (TRK)(TIE )
01 = UNIT 01 = DSBL (TRK)(TIE )
...one line for each channel...
23 = UNIT 23 = DSBL (TRK)(TIE )
ENLU/DISU
Syntax:
ENLU <channel TN>
DISU <channel TN>
Enables or disables the specified unit on the VGMC. Use this command to
troubleshoot problems with gateway calls. You can force a test call to use
a specific set of channels by disabling the others.
The following table describes the command parameters.
Table 106
Command parameters
Parameter Value Description
card TN
l s c u Terminal Number of the gateway channel for the card
The following example shows command output.
.enlu 2 3
.stat 2 3
IDLE
.disu 2 3
.stat 2 3
DSBL
IDC
Syntax:
IDC <card TN>
Print information about the VGMC.
This command sends a query to the card XA8051 processor. Use this
command to troubleshoot card lockup problems. Based on the response or
lack of response, you can determine the state of the card.
The following table describes the command parameters.
Nortel Communication Server 1000
Troubleshooting Guide for Distributors
NN43001-730 02.02 31 December 2009
Copyright © 2008-2009 Nortel Networks. All Rights Reserved.
.